Override Control Setup#

_images/Screenshot_Override.png

Runtime Elements#

  • Target Type

    • Group (default)

    • Fixture

  • Number

    • Group or Fixture object number to control

    • If group is selected for target type a group number of 0 will control ALL fixtures

  • Fade Time (secs.)

    • Fade time when setting or releasing the override in seconds (default 0)

  • Crossfade Path

    • Default (default)

      • Will use the path set within the controller configuration which is typically set to Linear

    • For a detailed explanation of the following paths please refer to the Designer manual

      • Linear

      • Start

      • End

      • Braked

      • Accelerated

      • Damped

      • Overshoot

      • Col At Start

      • Col At End

      • Int At Start

      • Int At End

      • Colour First

      • Intensity First

  • Release Override

    • Releases the override

    • If a timeline or scene was previously playing prior to the override being set the timeline or scene will output upon the release of the override

  • Hex RGB Colour

    • Intended to interface the Q-SYS Colour Picker component to this plugin for colour mixing capabilities

    • The IRGB sliders will track the levels that the Colour Picker component are set to

    • Entering a 3 byte RGB level into this field will also update the IRGB sliders as well (e.g. #FF7F40)

      • The Colour Picker component will not update based on input to this control

      • The background colour of this control will update based on Colour Picker input or movement of the IRGB sliders

  • Colour Parameter & Intensity Sliders

    • Allows for 0-255 level control of the parameters selected within the Parameter Selection dropdown menu

    • Levels will not be sent until the Send Parameter Selection Levels button/pin has been triggered

      • Levels output are limited to the Parameter Selection chosen within the Parameter Selection dropdown menu

        • For example, if IRGB is selected as the Parameter Selection only intensity, red, green and blue slider levels will be sent once the Send Parameter Selection Levels button/pin is triggered

  • Parameter Selection

    • Intensity (default)

      • Formats command with intensity levels of the selected target

    • Intensity + CCT

      • Formats command with intensity and colour temperature levels of the selected target

    • CCT

      • Formats command with colour temperature levels of the selected target

    • IRGB

      • Formats command with intensity, red, green and blue levels of the selected target

    • HSI

      • Formats command with hue, saturation and intensity levels of the selected target

    • IRGB + CCT

      • Formats command with intensity, red, green, blue and colour temperature levels of the selected target

    • HSI + CCT

      • Formats command with hue, saturation, intensity and colour temperature levels of the selected target

  • Send Parameter Selection Levels

    • When triggered the Parameter Selection levels will be sent based on the level the Parameter Sliders are set to and the Parameter Selection dropdown

Designtime Properties#

Control Pins#

Pin Name

Input

Output

Values

Disable

0/false, 1/true

Override Fade Time

number

Override Hex RGB Colour

number

Override Number

string

Override Parameter Selection

string

Override Path

string

Override Target

string

Override Release

string

Override Send Selected Parameters

momentary true/false

Override Blue Level

0-255

Override CCT Level

0-255

Override Green Level

0-255

Override Hue Level

0-255

Override Intensity Level

0-255

Override Red Level

0-255

Override Saturation Level

0-255